Quartz Tube Disinfection UV/Ozone Lamp 185/254nm 32W 220V/110V

Name

Quartz tube disinfection lamp (no ozone/with ozone)

Size

190*530mm

Power

38W

Mmaterial

Hardware + baking paint

Remote control

Adjustable 15-30-60 minutes

Light Source type

Quartz ultraviolet light source

Area

40㎡

Warranty

1 year

PC/CTN

6

N.W.(kgs)

7.5

G.W.(kgs)

11.4

Product Details

FAQ

1. How many sterilization modes do a sterilization lamp have?
    Have two ways:  UV   and    Ozone

2. What’s the difference between them?
    *UV : wavelength: 253.7nm     How to Sterilize: ultraviolet radiation to sterilize,  Destroy or change DNA      Type: Physical
    *Ozone :wavelength: 185nm      How to Sterilize: It turns oxygen into ozone ( O2→O3 ),  Strong oxidation      Type: Chemical

3. How does the sterilization lamp work?
    Ultraviolet sterilization lamp is actually a low-pressure mercury lamp. Low-pressure mercury lamps are made using a lower mercury vapor pressure.10-2pa) are activated to emit ultraviolet light. There are two main spectral lines: one is a wavelength of 253.7nm; The other is at 185nm, both of which are invisible to the naked eye.

4. What are their advantages and disadvantages?
    *UV :Advantage: Simple, convenient, broad-spectrum and efficient, without secondary pollution, go inside the room immediately after turn off light(Disadvantage: Cannot kill all the bacteria and viruses where is out of light range, the shadow place might rest of bacteria).
    *Ozone :Advantage: O3 can kill all bacteria and viruses in the air(Disadvantage: O3 is dangerous for the body, people need around 15-30mints to open window for ventilation)

5. Can I choose UV+Ozone?
     No, because they are indifferent wavebands, they cannot exist at the same time. (UVC: 253.7nm; Ozone:185nm)You can choose UV or Ozone according to your needs.

6. What is the workflow of sterilization lamps?
    *UV: Turn on the lamp—People leave the room—Sterilize 15-30mins—Turn off the lamp—Enter the room
    *Ozone: Turn on the lamp—People leave the room—Sterilize 15-30mins—Turn off the lamp—Open windows for ventilation 15-30mins—Enter the room

7. Why is the tube of sterilization lamp quartz glass?
     Because UV can only penetrate quartz glass, can not penetrate any other material.

8. What function does the sterilization lamp have with the sensor?
     The function of PIR sensor: when lamp lighting, if people within 5 meters distance of lamp, the lamp will power off automatically; When people left, the lamp will restart after about 55 seconds automatically.

9. Does the sterilization lamp have a timing function?
    Yes, adjustable 15 minutes, 30 minutes, 60 minutes.

10. Can people stay in the room while the sterilization lamp is working?
     No, both UV and Ozone harm the human body.

Product Specification

Multi-function high-efficiency sterilization lamp isa new designultraviolet sterilizing lamp with the functions of sterilization, disinfection, mites removal and formaldehyde removal, mainly forhome and public environment use. Ultraviolet kill microorganisms (bacteria, viruses, sporesand other pathogens) through radiation damage to microorganisms and destroy the function of nucleic acids, to achieve the purpose of disinfection.

      Matters attention:

  1. This product is only for indoor use, to avoid moisture and vibration.
  2. Do not cover when using the lamp.
  3. People and animals are not allowed on site when using the lights,please do not look at the lamp with your eyes to avoid eyeand skin damage.
  4. Long time to contact the ultraviolet can harm to the humanbody (animal)/ eyes,so the doors and windows need to be closed when sterilization is dosed, and people and animals need to leave.
  5. After sterilization, please ventilate the space for 30-60 minutes before entering, if smell irritant smell need to extend the ventilationtime to enter again.
  6. Please wipe the lamp with a clean towel to keep the sterilization effect.
  7. Frequency of use: it is recommended to use it once or twice a week for about 30 minutes each time. 8.1n the case of remote control broken or lost, can be inserted twicein succession plug. The second time after the sterilization lamp will flash,delay 15 seconds light automatically on, work 30 minutes automatically off.
  8. Note that the remote control is used in one-to-one pairing.lt is recommended to pull the plug after use and avoid switching on and off lights with the same products in the nearby area.
  9. Buy of two or more sterilizing lamp, if one of the remote control is lost or damaged, other remote controls can be used as follows,long press the 60-minute timing button of the remote control (press it all the time), then insert the plug of the sterilizing lamp, after the light flashes for 3~5 seconds, the button can be released, indicating that the remote control and the light complete the automatic code program,and then press ON/OFF can be used normally.(Note: if one remote control is needed to control multiple lights, the disinfection lights should be separated from each other in different rooms.)
  10. Press on on/off first when using, the light will flash to indicate that the light has been turned on; Then press the button to set the timingfat the same time the light flashes),then the sterilization lamp will automatically delay the start of work after 15 seconds, after reaching the set working time will automatically dose.(the sterilizing lamp has three timing: 15/30/60 minutes, and the time set by the product will not stack)

Details about Quartz Tube Disinfection UV/Ozone Lamp 185/254nm 32W 220V/110V

ONE STEP TO KILL GERMS

Transmit 253.7NM ultraviolet short wave 3600 super sterilization.
UV rays destroy biological DNA and RNA, rendering it incapable of reproduction.
Thereby dying and reaching the effect of sterilization.

Quartz Tube Disinfection UV/Ozone Lamp can be used in a wide range of applications, such as hospitals, schools, supermarkets, hotels, restaurants, kitchens, living rooms, etc.

Only one key control is required,  3 different sterilization times can be actively selected, namely 15 minutes, 30 minutes, and 60 minutes.

Portable handle                                                                                       Nano metal coating
Extractable design for easy access                                                           Effective anti-corrosion

TUV disinfection tube                                                                            Through the wall remote control 
Quartz tube glass housing                                                                        Third gear timing

Our Certificate

CE / UL / TUV / ROHS / FCC / MSDS / EPA / Gmicro Testing Certified.

CONTACT US

Get Catalogue & Quote

Email

info@Darklessled.com

TEL

+8613929574789

Address

Guangzhou City, Guangdong Province.

Get Catalogue & Quote

    Get Catalogue & Quote

    *

    *

    *

    *